FIXED TYPE ULTRASONIC FLOWMETER

Ultrasonic flowmeters take measurements through the outside of the pipe with high frequency sound. While the transmitter sensor of the flowmeter, which takes measurements with the help of 2 sensors, sends high frequency sound waves into the pipe, the receiver sensor determines the velocity of the fluid according to the reception of this signal. In pipes of different materials, measurements can be taken easily from outside the pipe. In this way, there is no need to intervene on the pipe. They can take measurements from DN15 to DN6000 according to sensor sizes. The absence of an inner coating (concrete, fiberglass, etc.) in the pipes that these model flow meters will be used in, the fact that the pipes are not rusted, damaged, and their integrity is not impaired are important factors for measurement. Pipe connection lengths that can be used according to sensor sizes are listed below:

➢ TS1 : DN15 - DN100

➢ TM1 : DN50 - DN1000

➢ TL1 : DN300 - DN6000

➢ Immersion Type: DN15-DN6000

Ultrasonic flowmeters also offer continuous recording for up to 5 years with its recording feature. Usage areas of ultrasonic flowmeters are listed below:

➢ Water (Wastewater, Hot Water, Frozen Water, City Water, Sea Water, etc.)

➢ Sewage water containing small particles

➢ Oil ➢ Plant Wastes

➢ Liquid food

➢ Pure liquids

➢ Solvents and other liquids

 
 
Measuring Range
0.01 … 12 m/s
Feed
AC220V or DC24V
Power consumption
less than 1.5W
Communication Protocols
MODBUS, M-BUS, Fuji and other communication protocols
Optional Additional Feature
Calorie / Energy Calculation with 2 PT100s
Model
EUFF-2000S
Connection
DN15 - DN6000
Truth
Better than ±1%
Repeatability
better than 0.2%
Measurement Principle
Transition Time Measurement Principle
Measurement Period
500ms
Indicator
Backlit LCD, Instant / Total Flow, Temperature, Density etc. Indicators
Exit
4-20 mA or 0-10 V Analog Output; 0-1kOhm, 0.1% precision, Relay Output and RS485 Serial Output
Login
3 Analog Inputs, Opt. 3-Wire PT100 Input
Record
Automatically Adjusted 64 Days / 64 Months and 5 Years Recording Feature
Usable Pipe Material
Steel, Stainless Steel, Cast Iron, Copper, PVC, Aluminum, FRP etc. (provided that it is a liner)
Measurable Fluids
Water, Seawater, Industrial Wastewater, Acid / Base liquids, Alcohol, Beer and other homogeneous liquids
Temperature Range
Main unit -30°C - 80°C, Sensors -40 °C -110 °C
Humidity Range
85%RH
Cable
Sensor Max. Connection 20 meters, RS485 Max. Link 1000 meters
 
 

Get Technical Information

Please confirm that you have read and accepted the cookie policy.